Crack Indications on Steel Forgings - Magnetic particle Inspection of forgings at Trinity NDT
Crack Indications on Steel Forgings - Magnetic particle Inspection of forgings at Trinity NDT
Technique: Magnetic particle testing using Prod Type Technique
Current: AC - 700A at 150mm prod spacing
Particle type: Fluorescent -Magnaflux make Wet
Particle concentration: 0.3 ml /100ml
Black light intensity: 1200 microwatt/cm sq. verified by calibrated Radiometer
Type of magnetization: Circular
To know more about Trinity NDT Magnetic particle testing, training certification facilities visit: www.trinityndt.com