Crack Indications on Steel Forgings - Magnetic particle Inspection of forgings at Trinity NDT
Crack Indications on Steel Forgings - Magnetic particle Inspection of forgings at Trinity NDT Technique: Magnetic particle testing using Prod Type Technique Current: AC - 700A at 150mm prod spacing Particle type: Fluorescent - Magnaflux make Wet Particle concentration: 0.3 ml /100ml Black light intensity: 1200 microwatt/cm sq. verified by calibrated Radiometer Type of magnetization: Circular To know more about Trinity NDT Magnetic particle testing, training certification facilities visit: www.trinityndt.com